.. RAINBOW
.. THERMOSTAT ENVIRONMENT TEST REPORT
.. 2013-06-28 16:45:16
.. 6418
.. THERMOSTAT_Environment_Test(내열성, 내한성 테스트)_REV.00(130627).pdf 
* THERMOSTAT ENVIRONMENT TEST REPORT

 1. COLD TEST
    Leave the thermostat in the chamber of -25±3℃ for 48 hours and take the
    product out. Check if there's any condensation or drop of water.
    If condensation or drop of water is shown, clean it sufficiently and leave it for
    2 hours. Then carry out the test of Temperature test and check whether there's
    any problem in function by the change of temperature, crack, expansion,
    deformation or not. Carry out test of Insulation Resistance test and Eletric
    Strength test again.

 2. HEAT TEST
    Leave the thermostat in the chamber of 70±2℃ for 48 hours and take the product
    out. And leave it for 2 hours. Then carry out the test of Temperature test and
    check whether there's any problem in function by the change of temperature,
    crack, expansion, deformation or not. Carry out test of Insulation Resistance test
    and Eletric Strength test again.

Installation and operating instructions Ver1.0
ư
 
 
 
 
Rainbow Electronics Main Information
Company | Thermostat | Thermometer | Others | Customer Center | Online Inquiry | Sitemap
TS | RPT | RNTS | TNTS | TSR | RMT | TS-XXXSF | PTSC | PTSC-NC/NO | LTS | ITS | T103 | T125 | L117 | T115 | T109 | TMSA | TMRB | TMRC | TMRG |
Cartridge-Heater | Infrared Ceramic | KSD-302D Series | FC-Series